● 2 MPP trackers, Max. efficiency up to 98.6%
● Zero export application, VSG application
● String intelligent monitoring (optional)
● Wide output voltage range
● Anti-PID function (Optional)
| Model | SUN-30K-G04 | SUN-33K-G04 | SUN-35K-G04 | SUN-36K-G04 |
| Input Side | ||||
| Max. DC Input Power (kW) | 39 | 42.9 | 45.5 | 46.8 |
| Max. DC Input Voltage (V) | 1000 | |||
| Start-up DC Input Voltage (V) | 250 | |||
| MPPT Operating Range (V) | 200-850 | |||
| Max. DC Input Current (A) | 40+40 | |||
| Max. Short Circuit Current (A) | 60+60 | |||
| No.of MPP Trackers | 2 | |||
| No.of Strings per MPP Tracker | 3+3 | |||
| Output Side | ||||
| Rated Output Power (kW) | 30 | 33 | 35 | 36 |
| Max. Active Power (kW) | 33 | 36.3 | 38.5 | 39.6 |
| Rated Output Voltage/Range (V) | 3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un (this may vary with grid standards) | |||
| Rated Grid Frequency (Hz) | 50 / 60 (Optional) | |||
| Operating Phase | Three Phase | |||
| Rated AC Grid Output Current (A) | 45.5/43.5 | 50/47.8 | 53/50.7 | 54.5/52.2 |
| Max. AC Output Current (A) | 50/47.9 | 55/52.6 | 58.3/55.8 | 60/57.4 |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||
| Total Harmonics Current Distortion (THDi) | <3% | |||
| DC Injection Current (mA) | <0.5% | |||
| Grid Frequency Range | 45-55 or 55-65 (Optional) | |||
| Efficiency | ||||
| Max. Efficiency | 98.6% | |||
| Euro Efficiency | 97.8% | |||
| MPPT Efficiency | >99% | |||
| Protection | ||||
| DC Reverse-Polarity Protection | Yes | |||
| AC Short Circuit Protection | Yes | |||
| AC Output Overcurrent Protection | Yes | |||
| Output Overvoltage Protection | Yes | |||
| Insulation Resistance Protection | Yes | |||
| Ground Fault Monitoring | Yes | |||
| Anti-islanding Protection | Yes | |||
| Temperature Protection | Yes | |||
| Integrated DC Switch | Yes | |||
| Remote Software Upload | Yes | |||
| Remote Change of Operating Parameters | Yes | |||
| Surge Protection | DC Type II / AC Type II | |||
| General Data | ||||
| Cabinet Size (WxHxD mm) | 362×577×215 (Excluding Connectors and Brackets) | |||
| Weight (kg) | 23 | |||
| Topology | Transformerless | |||
| Internal Consumption | <1W (Night) | |||
| Running Temperature | -25 to +65℃, >45℃ Derating | |||
| Ingress Protection | IP65 | |||
| Noise Emission (Typical) | ≤50 dB | |||
| Cooling Concept | Smart Cooling | |||
| Permissible Altitude (m) | 2000 | |||
| Warranty | 5 Years | |||
| Grid Connection Standard |
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
|||
| Operating Surroundings Humidity | 0-100% | |||
| Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||
| Features | ||||
| Display | LCD1602 | |||
| Interface | RS485/RS232/Wifi/LAN | |||