● 2 MPP trackers, Max. efficiency up to 97.7%
● Zero export application, VSG application
● String intelligent monitoring (optional)
● Wide output voltage range
● Anti-PID function (Optional)
● Low start-up voltage of 80V
| Model | SUN-9K-G02P1-EU-AM2 | SUN-10K-G02P1-EU-AM2 |
| Input Side | ||
| Max. DC Input Power (kW) | 11.7 | 13 |
| Max. DC Input Voltage (V) | 550 | |
| Start-up DC Input Voltage (V) | 80 | |
| MPPT Operating Range (V) | 70-500 | |
| Max. DC Input Current (A) | 26+26 | |
| Max. Short Circuit Current (A) | 39+39 | |
| No.of MPP Trackers | 2 | |
| No.of Strings per MPP Tracker | 2+2 | |
| Output Side | ||
| Rated Output Power (kW) | 9 | 10 |
| Max. Active Power (kW) | 9.9 | 11 |
| Rated Output Voltage/Range (V) | L/N/PE 220/230V (Optional) 0.85Un-1.1Un (this may vary with grid standards) | |
| Rated Grid Frequency (Hz) | 50 / 60 (Optional) | |
| Operating Phase | Single Phase | |
| Rated AC Grid Output Current (A) | 40.9/39.1 | 45.5/43.5 |
| Max. AC Output Current (A) | 45/43 | 50/47.8 |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |
| Total Harmonics Current Distortion (THDi) | <3% | |
| DC Injection Current (mA) | <0.5% | |
| Grid Frequency Range | 45-55 or 55-65 (Optional) | |
| Efficiency | ||
| Max. Efficiency | 97.7% | |
| Euro Efficiency | 97.5% | |
| MPPT Efficiency | >99% | |
| Protection | ||
| DC Reverse-Polarity Protection | Yes | |
| AC Short Circuit Protection | Yes | |
| AC Output Overcurrent Protection | Yes | |
| Output Overvoltage Protection | Yes | |
| Insulation Resistance Protection | Yes | |
| Ground Fault Monitoring | Yes | |
| Anti-islanding Protection | Yes | |
| Temperature Protection | Yes | |
| Integrated DC Switch | Yes | |
| Remote Software Upload | Yes | |
| Remote Change of Operating Parameters | Yes | |
| Surge Protection | DC Type II / AC Type II | |
| General Data | ||
| Cabinet Size (WxHxD mm) | 336x410x213.5 (Excluding Connectors and Brackets) | |
| Weight (kg) | 14.95 | |
| Topology | Transformerless | |
| Internal Consumption | <1W (Night) | |
| Running Temperature | -25 to +65℃, >45℃ Derating | |
| Ingress Protection | IP65 | |
| Noise Emission (Typical) | ≤35 dB | |
| Cooling Concept | Free Cooling | |
| Permissible Altitude (m) | 2000 | |
| Warranty | 5 Years | |
| Grid Connection Standard | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | |
| Operating Surroundings Humidity | 0-100% | |
| Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |
| Features | ||
| Display | LCD1602 | |
| Interface | RS485/RS232/Wifi/LAN | |