● 2 MPP trackers, Max. efficiency up to 97.5%
● Zero export application, VSG application
● String intelligent monitoring (optional)
● Wide output voltage range
● Anti-PID function (Optional)
● Low start-up voltage of 80V
| Model |
SUN-3.6K-G04P1 -EU-AM2-P1 |
SUN-4K-G04P1 -EU-AM2-P1 |
SUN-4.2K-G04P1 -EU-AM2-P1 |
SUN-4.6K-G04P1 -EU-AM2-P1 |
SUN-5K-G04P1 -EU-AM2-P1 |
SUN-5.2K-G04P1 -EU-AM2-P1 |
SUN-6K-G04P1 -EU-AM2-P1 |
SUN-6.2K-G04P1 -EU-AM2-P1 |
| Input Side | ||||||||
| Max. DC Input Power (kW) | 4.7 | 5.2 | 5.46 | 5.98 | 6.5 | 6.76 | 7.8 | 8.06 |
| Max. DC Input Voltage (V) | 550 | |||||||
| Start-up DC Input Voltage (V) | 80 | |||||||
| MPPT Operating Range (V) | 70-500 | |||||||
| Max. DC Input Current (A) | 18+18 | |||||||
| Max. Short Circuit Current (A) | 27+27 | |||||||
| No.of MPP Trackers | 2 | |||||||
| No.of Strings per MPP Tracker | 1+1 | |||||||
| Output Side | ||||||||
| Rated Output Power (kW) | 3.6 | 4 | 4.2 | 4.6 | 5 | 5.2 | 6 | 6.2 |
| Max. Active Power (kW) | 3.96 | 4.4 | 4.62 | 5.06 | 5.5 | 5.72 | 6.6 | 6.82 |
| Rated Output Voltage/Range (V) | L/N/PE 220/230V (Optional) 0.85Un-1.1Un (this may vary with grid standards) | |||||||
| Rated Grid Frequency (Hz) | 50 / 60 (Optional) | |||||||
| Operating Phase | Single Phase | |||||||
| Rated AC Grid Output Current (A) | 16.4/15.7 | 18.2/17.4 | 19.1/18.3 | 21/20 | 22.8/21.8 | 23.7/22.7 | 27.3/26.1 | 28.2/27 |
| Max. AC Output Current (A) | 18/17.3 | 20/19.2 | 21/20.1 | 23/22 | 25/24 | 26/24.9 | 30/28.7 | 31/29.7 |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||||||
| Total Harmonics Current Distortion (THDi) | <3% | |||||||
| DC Injection Current (mA) | <0.5% | |||||||
| Grid Frequency Range | 45-55 or 55-65 (Optional) | |||||||
| Efficiency | ||||||||
| Max. Efficiency | 97.3% | 97.5% | ||||||
| Euro Efficiency | 97.5% | |||||||
| MPPT Efficiency | >99% | |||||||
| Protection | ||||||||
| DC Reverse-Polarity Protection | Yes | |||||||
| AC Short Circuit Protection | Yes | |||||||
| AC Output Overcurrent Protection | Yes | |||||||
| Output Overvoltage Protection | Yes | |||||||
| Insulation Resistance Protection | Yes | |||||||
| Ground Fault Monitoring | Yes | |||||||
| Anti-islanding Protection | Yes | |||||||
| Temperature Protection | Yes | |||||||
| Integrated DC Switch | Yes | |||||||
| Remote Software Upload | Yes | |||||||
| Remote Change of Operating Parameters | Yes | |||||||
| Surge Protection | DC Type II / AC Type II | |||||||
| General Data | ||||||||
| Cabinet Size (WxHxD mm) | 330×323×190 (Excluding Connectors and Brackets) | |||||||
| Weight (kg) | 8 | |||||||
| Topology | Transformerless | |||||||
| Internal Consumption | <1W (Night) | |||||||
| Running Temperature | -25 to +65℃, >45℃ Derating | |||||||
| Ingress Protection | IP65 | |||||||
| Noise Emission (Typical) | ≤35 dB | |||||||
| Cooling Concept | Free Cooling | |||||||
| Permissible Altitude (m) | 2000 | |||||||
| Warranty | 5 Years | |||||||
| Grid Connection Standard | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE-AR-N 4105 | |||||||
| Operating Surroundings Humidity | 0-100% | |||||||
| Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||||
| Features | ||||||||
| Display | LCD1602 | |||||||
| Interface | RS485/RS232/Wifi/LAN | |||||||